Eversafe Bus Duct Forced-Air Cooling Units: Engineering Innovation for Efficient, Reliable Cooling for Nuclear Power Customers_News_恒丰赛特实业(上海)有限公司

2026.11.13
Eversafe Bus Duct Forced-Air Cooling Units: Engineering Innovation for Efficient, Reliable Cooling for Nuclear Power Customers

Creat

Intelligent Bus Duct Cooling for Reliable Unit Operation

Eversafe Bus Duct Forced-Air Cooling Unit

Eversafe Bus Duct Forced-Air Cooling Units: Engineering Innovation for Efficient, Reliable Cooling for Nuclear Power Customers(图1)

In large-capacity generating and synchronous condenser projects for thermal power and new energy applications, isolated-phase bus duct current capacity, sealing reliability and lifecycle cost directly affect the safe, stable operation of the entire unit.

Eversafe Bus Duct Forced-Air Cooling Units: Engineering Innovation for Efficient, Reliable Cooling for Nuclear Power Customers(图2)

Drawing on its expertise in power plant auxiliary cooling systems, Eversafe has developed a bus duct forced-air cooling unit. Targeting leakage, excessive structural weight, high manufacturing costs and insufficient long-term reliability, it improves structural details to balance sealing, strength and economy, providing high-performance closed-loop cooling for large bus duct systems.



Current Industry Challenges

Conventional forced-air cooling units can suffer from poorly sealed flanges, air leakage, complex water-cooling enclosure assembly and heavy duct construction that wastes materials. These problems can make it difficult to maintain slight positive pressure inside bus ducts, allowing moisture and dust to enter and reducing insulation performance.

Starting from real operating conditions, Eversafe conducted structural simulations and multiple rounds of type testing to implement key technical improvements, achieving gains in both performance and cost efficiency.

Eversafe Bus Duct Forced-Air Cooling Units: Engineering Innovation for Efficient, Reliable Cooling for Nuclear Power Customers(图3)
Eversafe Bus Duct Forced-Air Cooling Units: Engineering Innovation for Efficient, Reliable Cooling for Nuclear Power Customers(图4)

Product Photos

Eversafe Bus Duct Forced-Air Cooling Units: Engineering Innovation for Efficient, Reliable Cooling for Nuclear Power Customers(图5)
Eversafe Bus Duct Forced-Air Cooling Units: Engineering Innovation for Efficient, Reliable Cooling for Nuclear Power Customers(图6)


Eversafe Bus Duct Forced-Air Cooling Units: Engineering Innovation for Efficient, Reliable Cooling for Nuclear Power Customers(图7)


Highlights of Eversafe's Bus Duct Forced-Air Cooling Unit

1. Optimized Main Flange Mounting Holes for More Reliable Sealing

To address leakage at flange connections, the fan cabinet's main flange mounting structure combines optimized bolt holes with dedicated sealing gaskets, eliminating leakage risks through improved assembly design. Professional pressure-retention testing showed a holding time more than 60% above the test standard requirement. The effective seal maintains slight positive pressure inside the bus duct housing, prevents moisture and dust ingress, reduces insulation flashover risk and meets the needs of continuous long-term power plant operation.

2. Redesigned Water-Cooling Enclosure Reduces Cost Without Compromising Reliability

After recalculating seal compression, the design combines a 10 × 10 sealing ring with a clamping plate. Precise control of seal deformation maintains sealing and pressure resistance. Rigorous testing confirmed that the structure meets operating requirements, while simpler manufacturing substantially reduces overall processing costs without reducing performance, balancing reliability and economy.

Eversafe Bus Duct Forced-Air Cooling Units: Engineering Innovation for Efficient, Reliable Cooling for Nuclear Power Customers(图8)

3. Simulation-Optimized 1060 Pure Aluminum Ducts for Lightweight Strength

Air ducts are essential to circulation. Eversafe used finite element analysis on welded 1060 pure aluminum duct assemblies to optimize their geometry and add internal frame reinforcement. While complying with national standards and maintaining overall performance, the design uses thinner sheet material to retain resistance to deformation and vibration, reduce aluminum consumption, lower weight and control material costs.

Eversafe Bus Duct Forced-Air Cooling Units: Engineering Innovation for Efficient, Reliable Cooling for Nuclear Power Customers(图9)

The complete bus duct forced-air cooling unit uses closed-loop cooling. Fans circulate air to remove heat generated by enclosed bus conductors. Integrated sensing, monitoring and control systems enable interlocked fan changeover, overtemperature alarms and condition monitoring. Suitable for large-generator isolated-phase bus ducts and synchronous condenser bus ducts, the system increases current-carrying capacity within the same housing dimensions and supports efficient operation.

Eversafe Bus Duct Forced-Air Cooling Units: Engineering Innovation for Efficient, Reliable Cooling for Nuclear Power Customers(图10)


Product Benefits

●Safer Operation: Multiple sealing improvements and excellent pressure retention keep the bus duct interior clean and dry, reducing insulation failure risk.

●Assured Performance: Simulation and testing verify the structural stability of the water-cooling enclosure and aluminum ducts under complex power plant conditions.

●More Economical Investment: Structural improvements simplify manufacturing and optimize material use, lowering equipment purchase costs without compromising performance.

●Broad Applicability: Suitable for forced-air cooling retrofits and new integrated installations of large-capacity isolated-phase bus ducts in thermal power, synchronous condenser and new energy projects.


Eversafe's Mission

Eversafe drives technical innovation through practical engineering needs and continues supplying highly reliable auxiliary equipment to the energy and power industry. Through detailed design improvements, its bus duct forced-air cooling unit enables safe heat dissipation and helps safeguard stable generating-unit operation.


Eversafe Bus Duct Forced-Air Cooling Units: Engineering Innovation for Efficient, Reliable Cooling for Nuclear Power Customers(图11)

For More Product Information,  Scan to Contact Us